Ampera
E182CC 7119 Triode Vacuum Tube
Also known as 7119 · CV5766Medium-gain triode for driver and line stage applications
Dual triodeHeater 6.3 V · 0.64 A9-pin Noval2 sectionsPhilips·Mullard 1960
- Plate dissipation
- 4.5W
- Max plate voltage
- 300V
- Amplification factor
- 24
- Transconductance
- 15mA/V
- Plate resistance
- 1.6kΩ
Characteristics
Datasheet values, once each. Every value cites its sheet.
HeaterIndirectly heated
| Heater voltageVh | 6.3 V | |
|---|---|---|
| Heater currentIh | 0.64 A |
Limiting valuesDatasheet maximum ratings — not to be exceeded
| Plate voltageVa max | 300 V | |
|---|---|---|
| Plate dissipationPa max | 4.5 W | |
| Cathode currentIk max | 60 mA | |
| Peak plate voltageVao | 600 V |
Mechanical
| Base | 9-pin Noval | |
|---|---|---|
| Rarity | Sought-after | |
| Pinout |
Small signalDatasheet parameters at the reference operating point — not limits
| Transconductance | 15 mA/V | |
|---|---|---|
| Plate resistance | 1.6 kΩ | |
| Amplification factor | 24 |
Capacitances
| Grid–cathode | 6 pF | |
|---|---|---|
| Grid–plate | 4 pF | |
| Plate–cathode | 1.1 pF |
Charactereditorial reading, not a measurement
| Gain | 24% | |
|---|---|---|
| Power | 11% | |
| Drive | 98% | |
| Linearity | 88% |
datasheet cited · model or editorial reading · catalogue value, no citation attached yet · nothing invented
Typical operation
Canonical operating pointModel
- B+
- 250 V
- Load
- 3 kΩ
- Va
- 150 V
- Ia
- 19.94 mA
- Vg
- -4.5 V
- Pd
- 2.99 W
- Gain
- 22.9 dB
- At Q
- Ayumi Nakabayashi
- μ
- 22
- gm
- 10.33 mA/V
- rp
- 2.1 kΩ
Using this tube
Applications
- Voltage amplifier
- Headphone output
- Phase splitter
Generic triode driver / preamp stage
Hi-Fi stereoHeadphone amp
Replace or compare
Sources
Manufacturer datasheets
SPICE models
Revision and verification status
- Source
- Philips·Mullard
- Reviewed
- 2026-05-29
- Status
- DataModelCalc
- Model
- Ayumi Nakabayashi
Context
The E182CC is a dual indirectly-heated triode from Philips·Mullard, introduced around 1960. It provides a gain factor (μ) of 24 with 1600Ω plate resistance. Commonly used in driver / preamp applications. SQ dual triode. High perveance.
History
- Introduced
- 1960
- Manufacturer
- Philips·Mullard
- Era
- Late Production
METRIX TESTER